Ocular parameters associated with visual performance of enhanced monofocal intraocular lens
Da Ran Kim, Young Chae Yoon, Woong-Joo Whang, Ho Sik Hwang, Kyung‐Sun Na
IF 1.7BMC Ophthalmology
초록

BACKGROUND: An enhanced monofocal intraocular lenses (IOLs) (Tecnis Eyhance ICB00 and Tecnis Eyhance Toric DIU) has been developed to enhance intermediate vision while avoiding the disadvantages of multifocal IOLs. Although many studies have demonstrated the improvement of intermediate visual acuity with enhanced monofocal IOLs, it is not known specifically for which patients these IOLs should be recommended or avoided. In this study, we aim to find out which ocular parameters affect vision performance and photic phenomenon of ICB00 or DIU at different distances. METHODS: Patients who underwent cataract surgery with ICB00 or DIU, performed by a single surgeon, were included. Before surgery, the patients' age, gender, axial length, anterior chamber depth, spherical aberration Z (4,0), vertical coma, horizontal coma, angle kappa (κ), angle alpha (α), and other ocular parameters were investigated. One month after surgery, uncorrected near visual acuity (UNVA at 40 cm), uncorrected intermediate visual acuity (UIVA at 66 cm), uncorrected distance logMAR visual acuity (UDVA), IOL decentration, and quality of vision (QoV) questionnaires were conducted. RESULTS: A total of 43 patients (58 eyes) were included. The results of the univariate linear regression analyses showed a negative correlation between spherical aberration and logMAR UNVA and UIVA (p = 0.003, β=-0.51 and p = 0.018, β=-0.23, respectively) and a positive correlation between angle α and logMAR UIVA (p = 0.036, β = 0.19). Deeper anterior chamber depth (ACD) was associated with poorer total QoV (p = 0.018, β = 14.43), particularly in glare, halo, blur, and fluctuation perception. A higher degree of IOL decentration tended to decrease UNVA and UIVA (Pearson correlation coefficient, r = 0.336 and r = 0.221, respectively); however, no significant effect was observed on UDVA (Pearson correlation coefficient, r = 0.042). CONCLUSIONS: In enhanced monofocal IOLs, a higher level of spherical aberration is associated with better performance in UNVA and UIVA, whereas a larger angle α has a negative impact. A deeper ACD negatively affects the QoV.

키워드
MedicineOphthalmologyGLAREVisual acuityComa (optics)OptometryCataract surgeryIntraocular lensIntraocular lensesMultifocal intraocular lens
타입
article
IF / 인용수
1.7 / 5
게재 연도
2024

주식회사 디써클

대표 장재우,이윤구서울특별시 강남구 역삼로 169, 명우빌딩 2층 (TIPS타운 S2)대표 전화 0507-1312-6417이메일 info@rndcircle.io사업자등록번호 458-87-03380호스팅제공자 구글 클라우드 플랫폼(GCP)

© 2026 RnDcircle. All Rights Reserved.