This study evaluated the efficacy of various cleaning chemical concentrations, contact times, water temperatures, and their combinations on membrane fibers sampled from the test module of a pilot water treatment plant for surface water, with the goal of recovering a permeability level comparable to that of a virgin module. Energy dispersive X-ray analysis revealed high concentrations of organic materials in the fiber samples as well as minor amounts of inorganic materials. The dual-cleaning process recovered permeability to typical levels for the virgin module, indicating successful restoration of performance. A response surface methodology analysis was performed using the experimental cleaning data. The most effective cleaning protocol involved the use of 2.0% citric acid at 40°C for 4 h, followed by 0.15% NaOCl at 40°C for additional 4 h. During this process, the scale structure was loosened by the acidic solution and then the organic matters from the combined structure and gel layer on the membrane surface were dissolved by the alkaline agent. Our study highlights the importance of implementing tailored cleaning protocols based on a detailed assessment of membrane conditions and selecting appropriate cleaning agents and conditions for optimal performance of the membrane module.