주요 논문
3
*2026년 기준 최근 6년 이내 논문에 한해 Impact Factor가 표기됩니다.
1
article
|
인용수 0
·
2025Diffuser-Supported Hyperspectral Near-Infrared Measurement for Sensitivity Enhancement in Analysis of Diverse Thin Sheet Samples
Haeseong Jeong, Jiwoo Cho, Jae‐Jin Kim, Hoeil Chung
Analytical Chemistry
A diffuser-supported hyperspectral near-infrared (DS-HS-NIR) measurement scheme in which a Teflon plate as a photon diffuser was placed beneath a thin sheet sample for trans-reflectance spectral acquisition was proposed to enhance the peak intensity (sensitivity) of the sample. The scheme was to increase the number of sample-interacting photons by generating diffused photons using a Teflon (diffuser) and directing them toward a spectroscopic sampling area to additionally interact with a sample, increasing the intensity of the subsequent peak. When the weighing paper, plastic gloves, and mesh fabric sheets (thickness: 20-230 μm) were measured using a conventional scheme without using the diffuser, peaks corresponding to the sheet samples were difficult to recognize; with the diffuser, they were apparent with enhanced intensity. Furthermore, the increased number of sample-interacting photons when using the diffuser was confirmed by a Monte Carlo simulation. Next, to evaluate its real usage, we attempted to determine the crude protein contents in dried laver sheets (thickness: 210-480 μm). When the diffuser was employed, peaks centered at 1181 and 1461 nm corresponding to the organic constituents of laver sheets were distinct; these peaks were not observed in the measurement without a diffuser. Due to the peaks with enhanced intensity, the determined crude protein contents were well correlated with those based on conventional Kjeldahl analysis.
https://doi.org/10.1021/acs.analchem.5c01349
Chemistry
Hyperspectral imaging
Sensitivity (control systems)
Diffuser (optics)
Near-infrared spectroscopy
Infrared
Analytical Chemistry (journal)
Remote sensing
Environmental chemistry
Optics
2
article
|
gold
·
인용수 3·
2025Efficacy and safety of home-based transcranial direct current stimulation as adjunct treatment for cognitive improvement in major depressive disorder: A double-blind, randomized, multi-site clinical trial
C Lee, K. Park, Jeong Yeal Ahn, Yoonjeong Jang, YS Park, Hyeona Yu, Daseul Lee, HK Ihm, Jennifer Lee, Jae‐Jin Kim, Yi Lee, Sela Lim, Sarah Soonji Kwon, Hyun Gyu Park, Tae Hyon Ha, In‐Young Yoon, Woojae Myung, Ji Hyun Baek
European Psychiatry
Home-based tDCS for MDD demonstrated no evidence of effectiveness but was safe and well-tolerated. Further research is needed to address the technical limitations, evaluate broader cognitive functions, and extend durations to evaluate its therapeutic potential.
https://doi.org/10.1192/j.eurpsy.2024.1811
Adjunct
Transcranial direct-current stimulation
Medicine
Deep transcranial magnetic stimulation
Randomized controlled trial
Double blind
Cognition
Physical medicine and rehabilitation
Clinical trial
Brain stimulation
3
article
|
인용수 0
·
2025Automated Top Stitching via Vision-Based Macro-Mini Approach: Retrofitting Legacy Machines for Enhanced Precision in Garment Manufacturing
Taehwan Kim, Hyunwoong Choi, Jae‐Jin Kim, Byung‐Hyun Song, Ho‐Young Kim, Yong‐Lae Park
IEEE Transactions on Automation Science and Engineering
The apparel industry is increasingly adopting automation technologies and investing in research to address global reshoring efforts and rising labor costs. One essential process for automation in garment factories is top stitch, which involves sewing two fabric sheets together along a seam line while maintaining a consistent distance from it. This paper presents an automated top stitch system that retrofits a legacy machine using a vision-based macro-mini approach. The system mainly comprises a two-degree-of-freedom automatic sewing machine as the legacy machine, a vision sensor module, a mini-actuator module, and an infrared sensor module. The vision sensor module detects the seam line on the fabric, even in the presence of positional uncertainties, such as, human errors. The infrared sensor module monitors the sewing sequence, while the mini-actuator module operates simultaneously with the sewing machine to compensate for any misalignment. The system demonstrates improvements, with the average and the maximum errors reduced by 79% and 67%, respectively, and the standard deviation improved by 73%, compared to those from the operation without our system. To the best of our knowledge, this is the first development of an autonomous top stitch system using a retrofitted legacy machine, presenting a novel architecture that integrates sensors and actuators through a macro-mini approach.
https://doi.org/10.1109/tase.2025.3605235
Image stitching
Macro
Retrofitting
Machine vision
Computer science
Engineering
Engineering drawing
Embedded system
Artificial intelligence
Manufacturing engineering