주요 논문
3
*2026년 기준 최근 6년 이내 논문에 한해 Impact Factor가 표기됩니다.
1
article
|
gold
·
인용수 1·
2025Comparative study on setup accuracy of marker-less surface-guided radiation therapy versus traditional skin marks in hypofractionated whole breast irradiation: A marker-free approach starting from CT simulation
Yuri Jeong, Jung Hoon Kim, Jeong Geun Oh, Kang Kyoo Lee, Sun Rock Moon
Journal of Radiation Research and Applied Sciences
To evaluate the setup accuracy of surface-guided radiation therapy (SGRT) compared with traditional skin marks in patients undergoing hypofractionated whole breast irradiation, with a specific focus on our institution's practice of full eliminating skin marks from the computed tomography (CT) simulation. We retrospectively reviewed 184 breast cancer patients treated with hypofractionated whole breast irradiation between January 2022 and May 2023. Initial patient positioning was performed using either traditional skin marks (n = 93, 1488 sessions) or surface-guidance technology via AlignRT (n = 91, 1456 sessions). The setup accuracy was evaluated by analyzing translational couch shifts in vertical, longitudinal, and lateral directions through daily verification using orthogonal kV images in anterior-posterior and lateral directions obtained after initial positioning. The time from initial patient positioning to treatment was also compared. The average translational couch shifts after initial positioning with skin marks were 3.2 ± 1.8 mm, 3.3 ± 1.5 mm, and 2.8 ± 1.4 mm in the vertical, longitudinal, and lateral directions, respectively. For SGRT, the average translational couch shifts were 3.5 ± 1.5 mm, 3.3 ± 1.4 mm, and 2.8 ± 1.2 mm, respectively. There were no significant differences between SGRT and skin marks in any direction. The average time from initial patient positioning to treatment was shorter in patients with SGRT compared to those with skin marks, 261 s vs. 281 s. The elimination of skin marks from the CT simulation stage, facilitated by SGRT, resulted in comparable setup accuracy with traditional skin marks. In addition, SGRT significantly reduced the time from initial patient positioning to treatment, suggesting that SGRT can be effectively used in hypofractionated whole breast irradiation without the need for skin marks, potentially enhancing patient comfort and convenience.
https://doi.org/10.1016/j.jrras.2025.101290
Irradiation
Radiation therapy
Nuclear medicine
Biomedical engineering
Medicine
Materials science
Optics
Physics
Internal medicine
Nuclear physics
2
article
|
인용수 1
·
2022UNWANTED RADIATION EXPOSURE TO RADIOSENSITIVE ORGANS DURING HAND CT
Dae Jin Nam, Sun Rock Moon, Hong Je Kang
IF 1 (2022)
Radiation Protection Dosimetry
This study aimed to investigate unwanted radiation exposure of radiosensitive organs during computed tomography (CT) scans of the hand. Furthermore, we investigated the effectiveness of a shield in reducing unwanted radiation exposure. In a prospective observational study, the patients were randomized to receive a shield during the hand CT scan. Two group of patients were further randomized to undergo multi-detector CT (MDCT) or cone-beam CT (CBCT). The radiation dose was measured in the target point and the nearest skin surface of radiosensitive organs by attached the thermoluminescent dosemeter chips. When shielding was performed, the radiation doses had decreased significantly with a mean of 79% (65-91%) in the MDCT group and 88.6% (85-93%) in the CBCT group. In the non-shielded group, the radiation doses to the radiosensitive organs decreased inversely with increasing distance, which means that the closer the target point is, the more unwanted radiation exposure increases. It is important to keep radiosensitive organs as far as possible from the target point during CT scan. In particular, it is necessary to shield the radiosensitive organs closer to the target point. Level of Evidence: Level II, Prospective observational study.
https://doi.org/10.1093/rpd/ncac021
Medicine
Nuclear medicine
Radiation exposure
Radiation protection
Radiology
Radiation dose
Radiation therapy
3
article
|
인용수 5
·
2020Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
Yuri Jeong, Jeong Geun Oh, Jeong Ku Kang, Sun Rock Moon, Kang Kyoo Lee
Radiation Oncology Journal
The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer.
https://doi.org/10.3857/roj.2020.00066
Medicine
Prostate cancer
Nuclear medicine
Prostate
Radiation therapy
Radiation treatment planning
Dose-volume histogram
Rectum
Cancer
Radiology