IR-dyeing machine MODEL ACE-6000T
Pot 150ml×16EA×2Chamber Max. Temperature RT ~ 150℃ Speed Control inverter(CW.CCW) Heater Ceramic Infrared Heater(4kw×2Chamber) Cooling System Water Air Circulation System Chamber Size(in) 420×312×800×2Chamber Chamber Size(out) 11300×830×800mm Power 220V 50/60Hz, IP
UV-Vis Spectrophotometer
Fast results UV-Vis spectral acquisition and analysis in less than 1 second Excellent reproducibility stable optics, low noise electronics, no moving parts Simple operation task-oriented and application software, direct access to cells and cell holder Effortless servicing pre-aligned deuterium and tungsten lamps exchanged easily Good laboratory practices (GLP) self-test and revisions built into the software/firmware Pharmaceutical compliance regulated software for European and US pharmacopoeia Flexible accessories autosamplers, thermostatted cell holders, multicell transports, sipper systems
Spectophotometer
Instrument Type Dual beam integrating sphere with xenon flash lamp Measuring Geometry Diffuse illumination, 8° viewing in conformance with CIE publication No. 15.2 Colorimetry Illumination Source Pulsed xenon, filtered to approximate D65 Spectral Analyzer Proprietary SP 2000 analyzer with dual 256-diode array and highresolution holographic grating Wavelength Range 400-700 nm Photometric Resolution 0.003% Aperture Configuration Large Area View: 22 mm Small Area View: 9 mm Ultra-Small Area View: 6.5 mm Performance - Repeatability* 0.05 CIELAB E on white ceramic Performance - Reproducibility* 0.2 CIELAB E average of 12 BCRA tiles Absolute Operating Environment 5° to 40° C, 20-85% RH, non-condensing Warranty 1-year parts and labor - Extended warranty available
Spectrofluorophotometer
Light source 150W Xenon Lamp(Ozone resolving type lamp housing) Excitation/emission 900 grooves/mm Wavelength scale 220~900nm Wavelength 220~750nm(standard), 220~900nm(Option) Band width 1.5, 3, 5, 10, 15, 20 nm 6 step Wavelength accuracy ±1.5 nm Sensitivity S/N=150 over sensitivity accuracy HIGH and LOW. Wavelength switch velocity almost 20,000nm/min. Display iquid crystal (320X200) Size 667W x 530D x 270H, 43Kg Power 100/120/220/240V, 450VA
pH meter Model MP220
Measuring Range:from 0.00 to 14.00pH mV ±1999 Temp(˚C) -5.0 to 105.0 pH Calibration Points 2 from 10 Calibration Prompt
Cyclicvoltammetry (CV) electrode
Voltage Measurement Current measurement Voltage range ± 10V Current ranges Auto-ranging (8 ranges) Voltage resolution 6μV 650mA to 200nA (8 ranges) Voltage accuracy ±0.2% of reading, ±0.2% of range 2A to 200nA (with option) - Current resolution 120fA - Current accuracy (DC) ±0.2% of reading, ±0.2% of range - Bandwidth 1MHz (signal ≥2mA range typical) - Bandwidth limit filter Yes
UV curing Machine
Lamp power switch function The unit is equipped with a function to switch lamp power (200W/250W) to increase the degree of freedom for the irradiance setting. If high illumination is unnecessary, switching to 200W reduces power consumption by approximately 20% compared to the 250W setting. Environmental friendliness All PC boards in the SP-9 are free of lead. User manuals (in Japanese, English and Chinese) are also distributed on CD-ROM. Lamp replaceable from either side It is possible to replace a lamp from either the left or right side of the cabinet. This facilitates replacement without the need to move the cabinet. Operable at any voltage The SP-9 automatically handles input voltages ranging from AC90V to 264V. No modification or switching is required when the unit is used overseas
Cart wish Ultrasonic cleaner
Tank dimensions 11.5"L X 9.5"W X 6.0"D Overall dimensions 16"L X 15.5"W X 14.5"D Capacity 2.5 gal(US) Weight 14 Pounds Frequency 40kHz